Motion detector
Nominal power (W)
Power
Power factor
Dimensions of protective cover
(mm)
Dimensions L x W x H (mm)
Weight (g)
Max projected area (m²)
This product is suitable for indoor and outdoor lighting purposes.
The spotlight must be installed at a height of less than 3 m. Recommended installation height
for models with motion detector 1.8 to 2.5 m.
The spotlight must not be used for other purposes.
INSTALLATION AND CONNECTION TO POWER SUPPLY
1. Always switch off the power supply before installation (Fig. 1).
2. Installation position: The spotlight should ideally be fastened with the wall bracket.
3. Remove the retaining bracket from the spotlight (Fig. 2).
4. Mark the position of the drill holes for fastening the retaining bracket (Fig. 3) and drill the
corresponding holes in the wall (Fig. 4). Fasten the bracket to the wall with suitable screws
(Fig. 5).
5. Bring the connection line in through a cable sleeve with a seal (Fig. 6.1).
6. Guide the 3 wires into the screw terminal and screw them all tight (Fig. 6.2).
Pay attention to the markings N = blue wire, earthing symbol = green / yellow wire,
L = brown wire.
7. Plug the screw terminal into the spotlight's cable entrance (Fig. 6.3).
8. Push the cable sleeve in toward the spotlight and screw it to the spotlight cable entrance
(Fig. 6.4).
9. Fasten the spotlight to the retaining bracket.
10. Adjust the lamp into the desired position and tighten the screws (Fig. 7).
11. Switch the power supply back on (Fig. 8).

DESCRIPTION OF FUNCTION

(only for versions with motion detector) (Fig. 9 + 10)
This lamp is equipped with an infrared sensor. It switches on automatically when the
sensor detects movements in the area. If possible, do not point the motion detector toward
swimming pools, heating air extractors, air conditioners or objects subject to strong
temperature variations. Avoid directing the motion detector at trees or buses or places where
pets frequently are.
The motion detector can be rotated horizontally right and left as well as vertically up and
down.
8 8
20P123 Mobiler LED Strahler AL 0533153 210423.indd 8
20P123 Mobiler LED Strahler AL 0533153 210423.indd 8
AL 1050
AL 2050
AL 3050
No
No
No
10
20
30
0.09 A
0.16 A
0.135 A
0.5
0.5
0.9
118 x 76
171 x 117
204 x 140
93 x 124 x
180 x 135 x
216 x 165 x
101
111
136
331
523.8
754
0.0116
0.0243
0.0357
AL X050, AL X050 P
AL 1050 P
AL 2050 P
AL 3050 P
Yes
Yes
Yes
10
20
30
0.09 A
0.16 A
0.135 A
0.5
0.5
0.9
118 x 76
171 x 117
204 x 140
150 x 124 x
180 x 194 x
216 x 220 x
107
117
136
399.6
594.2
843
0.0186
0.0350
0.0476