FAULTS AND DAMAGES

If there is any reason to suspect that the safety of the device has been compromised, it must
be withdrawn from use and removed from any ex-hazardous areas immediately. Measures
must be taken to prevent any accidental restarting of the device. The safety of the device may
be compromised, if, for example:
Malfunctions occur.
The housing of the device shows damage.
The device has been subjected to excessive loads.
The device has been stored improperly.
Markings or labels on the device are illegible.
We recommend that a device displaying errors or in which an error is suspected be sent back
to i.safe MOBILE GmbH to be checked.

EX-RELEVANT SAFETY REGULATIONS

Use of this device assumes that the operator observes the conventional safety regulations and
has read and understood manual, safety instructions and certificate.
The following safety regulations must also be complied with:
Inside ex-hazardous areas the covers of all interfaces (USB, ISM interface) must be closed.
To ensure the IP-protection, it has to be ensured that all gaskets are present
and functional. There must be no large gap between the two halves of the housing.
The device may only be charged outside ex-hazardous areas.
Physical connections to IS330.2 are only allowed outside ex-hazardous areas using equip-
ment approved by i.safe MOBILE GmbH.
The IS-HS1.1 or IS-HS1.2 headset or other accessories approved by i.safe MOBILE GmbH may
be used within ex-hazardous areas only if connected to the ISM interface.
When using IS-HS1.1 or IS-HS1.2 headset or other accessories approved by i.safe MOBILE
GmbH, the equipment must be securely fastened to the ISM interface.
The device may only be charged at ambient temperatures between +5°C ... +35°C.
The device may not be exposed to any aggressive acids or alkalis.
The device may only be used in zones 2 or 22.
EX-RELEVANT SAFETY REGULATIONS FOR NORTH AMERICA
Conditions of Acceptability:
The battery may be charged outside explosion hazardous areas only using approved external
adapter model ICP12-050-2000B with output rated 5Vdc, 2A or other external approved AC/
DC adapter which also complies with the requirements of LPS and has output rated 5Vdc, 2A.
The battery may be replaced with an identical one outside of the explosion hazardous areas
only.
To ensure the IP64 protection, it has to be ensured that all gaskets are present and functional.
There must be no gap between the two halves of housing and between the battery cover and
housing.
The USB interface (type C) located at the left side is for data transmission and it is used in non
hazardous areas. It is not permitted to open the USB interface cover in hazardous locations.
The ISM interface of the device located at the right side can be used within hazardous areas
with approved headsets, Remote Speaker Microphones(RSM) and add-ons.