Hazard information
Please take the technical data (in particular the
maximum permissible switching capacity of the
load circuits and the type of load to be connected)
into account before connecting a load. Do not
exceed the capacity specified for the device.
For secure operation, the device has to be installed
in a power distribution panel according to VDE
0603, DIN 43871 (low-voltage sub-distribution
board), DIN 18015-x. The installation must be car-
ried out on a mounting rail (DIN rail) according to
EN 60715. Installation and wiring have to be per-
formed according to VDE 0100 (VDE 0100-410,
VDE 0100-510 etc.). Please consider the technical
connection requirements (TAB) of your energy
supplier.
The device has not been designed to support
safety disconnection.
Devices with electronic power supply units (e.g.
high voltage LED light sources) are no ohmic
loads. They can generate inrush currents with
more than 100 A. Switching such kind of loads
may lead to premature wear of the actuator. In
such cases, we recommend to use switch-on
current limiters at the switching outputs.