Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Troubleshooting; Protection Class - Hornbach FAN 2.0 Bersetzung Der Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Technical Data

GB
Trade mark
Model
Climate zone (Cold, Average, Warm)
kWh/(m
2 •
a)
Annual heating saved (kWh)
Annual electricity consumption
Type of ventilation unit
Type of drive installed
Maximum flow rate
Electric power input
Sound power level
Reference flow rate
Reference pressure difference
Specific power input (SPI)
Control typology
Max. internal/external leakage rate
Mixing rate of non-ducted ventilation
Visual filter change warning
Regulated exhaust grill installation
Internet address
Airflow sensitivity to pressure variations
Indoor/outdoor air tightness
124
FAN 2.0
FAN 2.0 100
C
A
W
-28/B
-12/E
-3/F
3355
1715
776
209 kWh
Unidirectional
Single speed
90 m
3
/h
15 W
56 dB(A)
3
0.018 m
/s
0 Pa
3
0.167 W/(m
/h)
manual control
2.7 %
not applicable
not applicable
none *)
www.hornbach.com
not applicable
not applicable
Nominal voltage
Frequency
Rated power
Current consumption
Degree of protection

Protection class

Speed
Max. airflow (Q)
Static pressure (Pt)
Ambient temperature (T)
Sound pressure level in 3m distance
*) Ensure, that precipitations, rainfall, birds, and animals do not penetrate
into ventilation system.

Troubleshooting

The device does not work
The impeller is not turning
220-240 V~
50 / 60 Hz
15 W
100 mA
IP34
/ II
2,400 rpm
90 m
3
/h
30 Pa
+1 °C ... +45 °C
36 dB(A)
There is no voltage.
Check the main switch and/or the
electrical connections.
Check that its movement is not
slowed down.
Check for objects obstructing the
impeller.
GB
125

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Fan 2.0 1006690124

Inhaltsverzeichnis