Use

Select operating mode

Function selector:
Press and hold the release button
function selector switch
selector switch
so that the required symbol
engages at the arrow mark:
Function
Drilling/screwing
Hammer drilling
Chiselling
Chisel position adjust-
ment
Adjusting chisel position:
You can rotate the tool to the required position for
chiselling using this function.
Turn the function selector switch
Turn the tool in the tool holder
position.
Turn the function selector switch
for the chiselling function.
PBH 1050 B2
on the
. Turn the function
Symbol
to position .
to the required
to position
Switching on and off
Switching the appliance on:
Press the ON/OFF switch
Switching the appliance off:
Release the ON/OFF switch
Switching to continuous operation:
Press the ON/OFF switch
pressed position with the ON/OFF switch lock
button
.
Switching off continuous operation:
Press the ON/OFF switch
again.

Preselecting rotational speed

You can use the speed preselector wheel
preselect the rotational speed.
Level A (low rotational speed) up to level F (high
rotational speed). The speed you select depends
on the material to be processed. Work out the right
setting with this practical test:
- Levels D–F: high rotational speed:
for hammer drilling/chiselling in concrete or
stone.
- Levels A–C: medium rotational speed:
for drilling in steel or wood.
.
.
. Lock it in the
and release it
to
GB