Remark:
1. During body fat test, it will display Err2 if hand pulse sensors get no-
input.
2. According to test result, 10 seconds have no operation or operation
arbitrarily key, will get into system recommendation to toughen pro-
gram.
TEST-Pulse Recovery:
It is a function to check the condition of pulse recovery that is scaled
from 1.0 to 6.0 while 1.0 means the best and 6.0 means the worst and
the increment is 0.1. In order to get rated correctly, users must test it
right after the workout finished by pressing „TEST" key and then stop
exercising. After the key is pressed, please also apply the heart rate de-
tector appropriately. The test will last for 1 minute and the result will
show in the display.
PULSE
1. Pulse Rate:
The whole set of heart rate detector include 2 sensors each side. Each
sensor has 2 pieces of metal parts. The correct way to get detected is
to gently hold both metal parts each hand. With the good signals pi-
cked up by the computer, the heart mark in the HEART RATE Display
shall flash. Sometimes the heart rate value is not useable, based on
wet hands or any other contact problems during exercising. If you need
high accuracy heart rate value you have to use an external heart rate
measurement with a pulse belt.
"WARNING" Heart rate monitoring system may be inaccurate. Over
exercise may result in injury or death. If you feel faint stop exercising
immediately.
WATT TABELLE
RPM and Power in Watt of Level 1 - Level 24 for AX 3000
Art.-Nr. 1907
LEVEL
20 RPM
30 RPM
WATT
WATT
1
4
8
2
6
11
3
7
13
4
8
16
5
9
19
6
10
21
7
11
23
8
13
27
9
15
29
10
16
31
11
17
35
12
18
37
13
19
40
14
20
43
15
22
46
16
23
50
17
25
53
18
26
56
19
28
59
20
29
63
21
31
65
22
32
67
23
34
71
24
36
74
Remarks:
1.The power consumptions (Watt) are adjusted by measuring the dri-
ving speed (min-1) of axle and the braking torque (Nm).
2.Your equipment was tested to fulfill the requirements of its accuracy
classification before shipment, If you have doubts about the accuracy,
please contactwith your local retailer or send it to accredited test labo-
ratory to ensure or calibrate it.
(Please note that a deviation tolerance as noted on page 15, is permis-
sible.)
Error Messages
Each time the computer is restarted, it will run a quick test for functio-
nality. If something is not okay, it indicates possible errors:
E 1 This symbol and a warning tone appear if the wiring is incorrectly
connected or there is a fault in the resistance setting. Check all cable
connections, especially at the connectors. After eliminating the error,
press and hold the „Start / Stop" button for 2 seconds to reset the sys-
tem to 0.
21
40 RPM
5 0 R P M
60 RPM
70 RPM
WATT
WATT
WATT
WATT
14
20
28
35
19
27
38
48
23
34
48
61
28
41
58
74
33
48
68
89
37
54
78
100
41
61
88
112
47
68
98
124
52
76
108
137
56
82
118
148
62
90
128
164
66
96
138
172
70
103
148
185
75
110
158
201
79
117
168
215
85
125
178
228
90
133
188
246
95
141
198
251
100
149
208
272
104
156
218
283
108
162
228
291
113
168
238
303
120
175
248
320
127
182
258
335
GB
80 RPM
WATT
42
60
77
93
110
125
142
159
176
187
203
220
236
252
269
286
304
318
332
346
361
378
397
416