Operation
The user can operate the window unit on the control panel of the F 1200+ drive.
The drive can also be activated by central commands from the building management technology GLT (automatic
mode). You will find information about this on the wiring diagram F 1200+ (ID 193235).
6. 1
Operation at the control panel
6. 1 . 1

Open/close the window in tilt position

Open the leaf
Close the leaf
6. 1 .2

Open/close the window in turn position

The turn position
Move the leaf to turn position
Press the turn position
X
(Turn) open the leaf manually. Use the drive housing as a handle element for this.
X
When the leaf has been turned open, all automatic ventilation commands are ignored.
Close the leaf from turn position
CAUTION!
Injuries caused by impact, crushing and pinching!
Make sure there are no body parts (hands, fingers) in the closing area of the leaf.
X
Close the leaf manually (press into closed position).
X
Press the turn position
X
The window is locked.
6. 1 .3

Open/close the window in turn position - variant with mechanical lock

Clear turn position
When the window is locked, open the lock on the upper side
X
cap (1) using the key (2).
Remove side cap.
X
The drive clears the turn position.
The turn position
Move the leaf to turn position
See chapter 6.1.2 "Open/close the window in turn position"
Close the leaf from turn position
See chapter 6.1.2 "Open/close the window in turn position"
Deactivate turn position
Insert the side cap again and lock.
X
The turn position is deactivated, the turn position
deactivated.
6. 1 .4
Interrupt automatic mode
When the window unit is controlled via building management technology, the drive is in automatic mode.
Before the drive moves automatically controlled, the LED status display flashes blue 3x.
You will find information about controlling with building management technology in the wiring diagram
F 1200+ (ID 193235).
Interrupt automatic mode
Press any key on the control panel.
X
Automatic mode is interrupted, the drive stops.
Press the tilt open
X
Press the tilt close
X
key is only activated if the window is closed and locked.
key for longer than 3 seconds until the window has unlocked completely.
key for longer than 3 seconds.
key is activated.
key.
key.
1
key is
Operation
2
23