13. — Trouble-shooting
• the motor will not start
- a fuse may have blown and needs replacing.
- the cable or the wall socket may be defective and
needs checking.
• the suction power is reduced
- the dust bag may be full and needs replacing,
- the filter may be clogged and needs shaking,
- The by pass valve is open
The by pass valve protects the motors against an
overheating that may occur when there is not enough
cooling air.
You should not release this mechanism unnecessarily
by closing the suction inlet with your hand while the
machine is working.
When the hose or the tube is blocked or the filter
needs to be cleaned, the airflow is interrupted or not
longer sufficient and the by pass valve opens. It is not
necessary to shut down the system while removing the
blockage.
Having done that, you may continue with your work.
• the vacuum cleaner stops
- the thermal cut-out has switched off the motor as a
result of an obstruction of the hose, wand or nozzle.
Remove the cause of the obstruction.
- when the motor is cool, it will automatically start
again.
Specifications
Rated power W
DUST CLASS
FREQUENCY (Hz)
GROUNDED
Protection grade (moist., dust) –
Airflow without hose l/sec – m3/h
Vacuum kPa - hPA
VACUUM MAX (KPA) – (HPA)
Suction power with hose W
Sound pressure level at 1.5 m Lpa – dB(A) (ISO 3744)
MAIN FILTER TYPE
Main filter area cm2
Exhaust filter, ULPA, surface area U15 cm2
Container capacity l
Dust bag capacity l
INLET (MM)
LENGTH X WIDTH X HEIGHT (CM)
Weight kg
Specifications and details are subject to change without prior notice.
40
All manuals and user guides at all-guides.com
IVT1000 CR
IVT1000 CR H
EU - UK
EU –UK
220-240V
220-240V
1200
1200
M
H
50-60
50-60
X
X
IP40
IP40
38 - 1368
35 - 1260
19,8 - 198
20 - 200
19,8 - 198
20 - 200
250
236
61
61
GORETEX PTFE
HEPA H13
2100
2573
2573
2573
12,5
12,5
6,5
8
32
32
Ø30 x 62,5
Ø30 x 72,5
7,75
9,2
IVT1000 CR
IVT1000 CR
IVT1000 CR H
Safe Pack
EU – UK
US
US
220-240V
110-120V
110-120V
1200
1100
1100
H
M
H
50-60
50-60
50-60
X
X
X
IP40
IP40
IP40
35 - 1260
36 - 1296
34 - 1224
20 - 200
19,6 - 196
19,8 - 198
20 - 200
19,6 - 196
19,8 - 198
236
240
232
61
61
61
HEPA H13
GORETEX PTFE
HEPA H13
2573
2100
2573
2573
2573
2573
-
12,5
12,5
6,5
6,5
8
32
32
32
Ø30 X 70
Ø30 x 62,5
Ø30 x 72,5
8,2
7,75
9,2
IVT1000 CR
Safe Pack
US
110-120V
1100
H
50-60
X
IP40
34 - 1224
19,8 - 198
19,8 - 198
232
61
HEPA H13
2573
2573
-
6,5
32
Ø30 X 70
8,2

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ivt 1000 cr h

Inhaltsverzeichnis