Maintenance and care
ATTENTION!
fTo unscrew the electrode, do not apply
irregular pressure, gradually increase
pressure until the thread is released.
The new electrode must be screwed into
its bracket and blocked but not tightened
up to the stop.
The burner sleeve
the central bore is damaged or if it has
expanded in comparison to a drilling of
a new nozzle. If the electrode
burner sleeve
8c
this can result in an overheating of the
parts. This can reduce the lift cycle of the
diffuser
8e
.
Once replaced, make sure the nozzle
clamping sleeve
sufficiently.
ATTENTION!
fThe nozzle clamp sleeve
be screwed on to the burner
has been equipped with the electrode
8d
, diffuser
8e
and burner sleeve
fIf these parts are missing, the
device may malfunction and it
may create a hazard for the
operating personnel.
22
GB/CY
8c
must be placed if
8d
or the
are replaced too late,
is tightened
8b
8b
must only
8
once it
8c
.
• Maintenance
PLEASE NOTE!
fThe plasma cutter must be regularly
maintained for perfect function and to
comply with the safety requirements.
Improper and wrong operation may
cause failures and damage to the
device. Have repairs only conducted by
qualified specialists.
Switch off the main power supply and
the main switch of the device prior to
carrying out maintenance or repair work
on the plasma cutter.
Regularly clean the outside of the plasma
cutter and its accessories. Use com-
pressed air, cotton waste or a brush to
remove dirt and dust.
In case of a defect or a necessary
replacement of equipment parts, please
contact the appropriate qualified person-
nel.
• Storage
If you will not be using the device for a
while, protect it from dust by storing it in a
clean and dry place.