Electrical Wiring
Special functions
1. Emergency switch:
Press the emergency switch in stop condition, indoor unit operates with AUTO, AUTO SPEED, 24 Setting
modes, pressure the emergency switch in start condition, indoor unit will stop operating.
2. Temp. consumption:
In heating mode, the temp. compensation range is -14 ~ 0.
Set the temp. consumption in Heating mode with the remote controller, heating mode; set 30 as the
reference point; press the sleep button 7 times, and the buzzer rings twice; the unit enters temp.
consumption mode. Temp. consumption data=current temp.-30
In cooling mode, the temp. compensation range is -7 ~ +7.
Set the temp. consumption in Cooling mode with the remote controller, cooling mode; set 23 as the
reference point; press the sleep button 7 times within 5 seconds; the buzzer rings twice; the unit enters
temp. consumption mode. Temp. consumption data=current temp.-23.
3. Energy saving setting:
When switched on, press the health button 8 times within 5 seconds; the buzzer will ring 4 short times
that the energy saving setting is valid; if the buzzer rings twice, the energy saving setting is invalid.
4. Compulsory Defrost:
In heating mode, with a high speed setting, the set temp. is 30, press the sleep button 6 times; the
buzzer will ring 3 short times, and the unit enters manual defrost mode.
5. Auto start function:
When switched on, press the sleep button 10 times within 5 seconds; the buzzer will ring 4 short times,
which indicates the enter auto restart function; press the sleep button 10 times within 5 seconds, and the
buzzer will ring twice indicating exit auto restart function.
Memory information: on/off conditions, mode, fan speed, setting temp., swing position.
6. Room card Function:
The Room card function can be accessed through the remote controller.
Press the light button 12 times with the remote controller. If the buzzer rings 4 times, the room card is
valid. If the buzzer rings twice, the room card is invalid.
7. Health anion function:
When switched on, press the "HEALTH" button, when displaying icon on the LCD display. The air
conditioner starts health anion function operation. Press the "HEALTH" button again to cancel the anion
function.
20