EN
18
Fitting guidelines
The cooker hob is manufactured to
work with two-phase alternating current
(400 V 2N~50 Hz). The voltage rating of
the cooker hob heating elements is 230 V.
Adapting the cooker hob to operate
with one-phase current is possible by
appropriate bridging in the connection
box according to the connection diagram
below. The connection diagram is also
found on the cover of the connection box.
Remember that the connection wire should
match the connection type and the power
rating of the cooker hob.
The connection cable must be secured in a
strain-relief clamp.
Replacing the mains supply cable
If the mains supply cable is damaged, then it must be replaced by an appropriate
replacement. The mains supply cable should be replaced in accordance with the
following instructions:
• Switch the appliance off at the control switch.
• Open the terminal block on the underside of the hob.
• Unscrew the terminal screws fixing the cable.
• The "green-yellow" earth wire must be connected to the terminal marked
must be about 10 mm longer than the live and neutral wires.
• The "blue" neutral wire must be connected to the terminal marked with letter (N) –
the live wire must be connected to the terminal marked with letter (L).
2
1
. It