Driver
3.
Remove the nut, bolt, and washers from the driver half of the coupling guard.
4.
Remove the driver half of the coupling guard:
a)
Slightly spread the bottom apart.
b)
Lift upwards.
5.
Remove the remaining nut, bolt, and washers from the pump half of the coupling guard.
It is not necessary to remove the end plate from the pump side of the bearing housing. You can
access the bearing-housing tap bolts without removing this end plate if maintenance of internal
pump parts is necessary.
6.
Remove the pump half of the coupling guard:
a)
Slightly spread the bottom apart.
b)
Lift upwards.
4
3
Item Description
1.
Annular groove
2.
Pump-side end plate
3.
Driver
4.
Pump half of the coupling guard
Model IC I-FRAME, ICI i-FRAME, ICH i-FRAME, ICIH i-FRAME Montage-, Betriebs- und Wartungshandbuch
1
2
5.2 Remove the coupling guard
49