Putting into operation
2. Press the test button on the second detector for approx. 2 seconds to set this
detector in addressing mode too.
3. The detectors exit addressing mode automatically after 60 seconds.
4. The addressing process can take up to 60 seconds. When the detectors have been
successfully trained, the LED on both detectors lights up for around 5 seconds,
after which the detectors exit addressing mode. If this was not successful, the
detector will return to standard mode automatically after 60 seconds.
5. If you wish to connect several detectors together,
you will need to define a central detector,
with which you can connect the other detectors.
Proceed with points 1 to 4 as described to connect
the detectors in a network.
6. The detectors will exchange their addressing data
with another.
Reset default factory settings/separate network connections
In order to reset the smoke detectors to the default factory settings
• Press the test button and hold it down.
• After approx. 2 seconds the LED will flash once a second. After another 5 seconds
the LED will flash more frequently (approx. twice a second).
• Now let go of the button. If a short beep is heard, the procedure was successful.
All network connections between the detectors have then been separated.
Muting the detector
If an alarm has been triggered, the wireless smoke detector can be muted by
pressing the test button. In the case of networked detectors, the mute button on
the activated detector can also silence the alarm of the other networked detectors.
– 32 –
Please note that in all other cases the muting only applies to the detector whose
test button has been pressed. The mute remains active until the alarm is automati-
cally reset. See the following table for differences in the signal when the detector
is muted.
Audible and visual signals
Mode
Audible
Standby
Testing
3 beeps 4 times
Smoke chamber
Beeps once every
fault
30 seconds
Restforing the
Short beep
factory settings
Fault in smoke
Beeps once every
chamber
30 seconds
Indivisual operation
Beeps once
Alarm
a second
Muting the detector –
Beeps once every
Low battery
30 seconds
Putting into operation
Visual
Notes
LED flashes every
30 seconds
LED flashes twice
a second
LED flashes twice
a second
LED flashes twice
LED flashes every
Acoustically and
30 seconds
visually out of sync
LED flashes twice
a second
LED flashes once
a second
LED flashes every
Acoustically and
30 seconds
visually in sync
– 33 –
GB