3 41 01 104 06 0.book Seite 18 Mittwoch, 2. Juli 2008 1:43 13
en
Safety warnings specific for wire brushing
operations
Be aware that wire bristles are thrown by the brush even
during ordinary operation. Do not overstress the wires by
applying excessive load to the brush. The wire bristles can
easily penetrate light clothing and/or skin.
If the use of a guard is recommended for wire brushing, do
not allow any interference of the wire wheel or brush with
the guard. Wire wheel or brush may expand in diameter
due to work load and centrifugal forces.
Additional safety warnings
Use elastic spacers/liners when these are provided with the
grinding accessory.
Make absolutely sure that the accessory is mounted in
accordance with the manufacturer's instructions. The
mounted accessory must be able to rotate freely. Incor-
rectly mounted accessories can loosen during operation
and fly off.
Handle accessories carefully and store them according to
the manufacturer's instructions. Damaged accessories can
form cracks and break off during operation.
When using application tools with a threaded insert, take
care that the thread in the application tool is long enough
to hold the spindle length of the power tool. The thread in
the application tool must match the thread on the spindle.
Incorrectly mounted application tools can loosen during
operation and cause injuries.
Do not machine any material containing asbestos. Asbestos
is cancerogenic.
Beware of any concealed electric cables, gas or water con-
duits; check the working area with a metal detector, for
example, before commencing work.
Use a stationary extraction system, blow out ventilation
slots frequently and connect a residual current device
(RCD) on the line side. When working metal under
extreme operating conditions, it is possible for conduc-
tive dust to settle in the interior of the power tool. The
total insulation of the power tool can be impaired.
Do not rivet or screw any name-plates or signs onto the
power tool. If the insulation is damaged, protection against
an electric shock will be ineffective. Adhesive labels are
recommended.
Always work using the auxiliary handle. The auxiliary han-
dle ensures reliable guidance of the power tool.
Before putting into operation, check the mains connection
and the mains plug for damage.
The value of the estimated weighted acceleration
obtained in the laboratory can serve for predicting the
exposure to vibration. During work, weighted accelera-
tions will be dependent on the particular application, and
deviation from this laboratory value can occur.
Intended use of the power tool:
hand-guided angle grinder for commercial use, for dry-
sanding/grinding and cutting metal and stone in weather-
protected environments using the application tools and
accessories recommended by FEIN.
18
This machine is also intended to be powered by a.c. gen-
erators with sufficient power output that correspond
with ISO 8528, design class G2. Compliance with this
Standard in particular is not given when the so-called dis-
tortion factor exceeds 10%. When in doubt, inform
yourself about the generator in use.
Operating instructions.
Putting into operation:
Please note: The accessory begins to move with short,
low-power impulses. The angle grinder thereby indicates
that the first pressing surface has been activated.
Please note: The angle grinder does not start up:
– when the switchpads at the front and rear are pressed
at the same time
– when the rapid-clamping lever is not tilted back and
engaged
– if one or more of the pressing surfaces is/are pressed
while the mains plug is inserted
Operation:
Only keep one of the 4 pressing surfaces permanently
pressed. The angle grinder remains at working speed.
Note: The switchpads actuate easily in order to prevent
tense working postures. Changing the working posture is
possible at any time by changing the switching position.
As long as the grinding accessory is not automatically
being braked, the angle grinder can be brought up to the
working speed again within 0.5 seconds by pressing one
of the 4 switchpads.
The self-start prevention lock prevents the angle grinder
from starting again on its own accord if the current sup-
ply has been interrupted during operation, even if only
for a short time, e.g. by pulling out the mains plug.
Repair and customer service.
Blow out the interior of the power tool at
regular intervals from outside through the air
vents with dry, compressed air.
Unscrew the clamping unit by hand to protect it from
damage and dirt.
If the supply cord of this power tool is damaged it must
be replaced by a specially prepared cord available
through the FEIN customer service centre.
If required, you can change the following parts yourself:
Application tools, auxiliary handle, clamping unit.

Warranty and liability.

The warranty for the product is valid in accordance with
the legal regulations in the country where it is marketed.
In addition, FEIN also provides a guarantee in accordance
with the FEIN manufacturer's warranty declaration.
Only part of the accessories described or shown in this
instruction manual will be included with your power
tool.