Controller module wireless
Parameter
General specifications
Dimensions (W x H x D)
Weight
Housing material
Operating temperature range
Ambient
Storage
Max. humidity
Supply voltage
Nominal voltage
Nominal power
(controller module only)
Fuse for thermostatic actua-
tors
Permissible cable type to
thermostatic actuators
The following components may be connected to one controller module
Room controllers
Thermostatic actuators
Electrical safety
Protection class
(EN 60730-1)
Degree of protection
(EN 60529)
Electromagnetic compatibility (EMC)
Emitted interference/immu-
nity
®
EnOcean
wireless
Radio Equipment Directive
(RED) 2014/53/EU
Table 4-3: Technical specifications controller modules wireless
(1)
The wireless system is only available in certain sales areas.
RoCon UFH
Product description
(1)
Controller module
RoCon UFH RMF2A
73 mm x 92 mm x 45 mm 162 mm x 92 mm x 45 mm
Per control circuit up to 4 Daikin UFH-Sat8
130 g
PC/ABS
-20 °C ... +60 °C
-20 °C ... +60 °C
Non-condensing
Via base module AC 230 V, DC 5 V
0.3 W
T 1 A
H03 VV-H2-F 2 x 0.75 mm²
Max. 2
II
IP 20
EN 61326-1:2013
See declaration of conformity
(enclosed with product)
Controller module
RoCon UFH RMF6A
260 g
0.5 W
T 3.15 A
Max. 6
EN
16