ENGLISH
if it is supposed to be leaved unused for a long time.
Cleaning the transducer
Clean with clean water or citric acid if there is scale in it.
Brush off the scale from the surface.
Rinse the transducer with clean water.
Cleaning the humidifier basin
Clean the water basin with soft cloth or use citric acid if there is scale in it.
If there is scale covering the security switch, drop citric acid for 2-5 mins on the scale and
clean it out with the brush.
Rinse the water basin with clean water.
5. TROUBLESHOOTING
Trouble
Possible cause
The humidifier is not plugged
in.
The light indicator is
off when switched
Power cord is damaged.
on
Humidifier is defective or
malfunctioning.
The light indicators
Humidifier is not turned on.
is on when switched
The target humidity is
on, but no mist
reached.
comes out
No water in the tank.
Water level is low.
The water level required
has not yet reached the
vaporisation compartment.
Water shortage
The water tank isn't well
indicator is on
positioned.
The humidifier isn't on a flat
surface.
The % RH of the room is over
90 %.
40
BREEZECARE 4000 CONNECTED
Solution
Plug the humidifier into a powered
electrical socket.
Stop using the device immediately
and contact the Technical Support
Service of Cecotec.
Press the power button to turn it on.
Increase the target humidity or
change mode.
Refill the water tank and wait at
least 1 minute.
Wait at least 1 minute.
Check the positioning of tank on the
base.
Check the positioning of the
humidifier.
Wait until the % RH gets lower.
Humidifier is new.
Dirty water or water sitting
Humidifier produces
too long.
an unusual smell
Residual smell from diffusing
aroma oil on the aroma
cotton.
Resonant in water tank when
water is too low.
Humidifier is on an unstable
surface.
Humidifier makes
a loud or unusual
Water tank is positioned
sound
incorrectly.
Humidifier is malfunctioning.
There is natural or artificial
air replacement in the room
which interfere the increase
of %RH.
The air inlet grids and nozzle
could be blocked.
The humidification
capacity is too low
Too much scale in the water
basin.
The humidity selected rate is
too low.
Water is too dirty or water
kept too long in the tank.
ENGLISH
Take out water tank, open cover, let
it stay 12 hours in cool position.
Clean water tank, fill with clear
water.
Remove the aroma cotton, rinse it
under clean water and allow it to
dry.
Fill water into water tank.
Move the humidifier to a stable flat
surface.
Turn off and unplug the humidifier,
then align the water tank cover with
its respective opening in the inner
chamber.
Stop using the device immediately
and contact the Technical Support
Service of Cecotec.
Check if doors and windows are
closed.
Check if there is no air conditioning
working in the room.
Remove any blocking items from
the grids and the nozzle.
Clean transducer.
Increase mist output speed.
Increase humidity setting rate.
Clean water tank, change to fresh
clear water.
BREEZECARE 4000 CONNECTED
41