Problem
The lamp does not work.
The compressor operates
continually.
Water flows on the rear plate
of the refrigerator.
Water flows into the refriger-
ator.
Water flows on the ground.
The temperature in the appli-
ance is too low.
The temperature in the appli-
ance is too high.
Replacing the lamp
Caution! Disconnect the plug from the mains
socket.
38
Possible cause
The lamp is defective.
The temperature is not set correctly. Set a higher temperature.
The door is not closed correctly.
The door has been opened too fre-
quently.
The product temperature is too high. Let the product temperature decrease
The room temperature is too high.
During the automatic defrosting
process, frost defrosts on the rear
plate.
The water outlet is clogged.
Products prevent that water flows in-
to the water collector.
The melting water outlet does not
flow in the evaporative tray above the
compressor.
The temperature regulator is not set
correctly.
The temperature regulator is not set
correctly.
The door is not closed correctly.
The product temperature is too high. Let the product temperature decrease
Many products are stored at the
same time.
There is no cold air circulation in the
appliance.
Refer to "Replacing the lamp".
Refer to "Closing the door".
Do not keep the door open longer than
necessary.
to room temperature before storage.
Decrease the room temperature.
This is correct.
Clean the water outlet.
Make sure that products do not touch
the rear plate.
Attach the melting water outlet to the
evaporative tray.
Set a higher temperature.
Set a lower temperature.
Refer to "Closing the door".
to room temperature before storage.
Store less products at the same time.
Make sure that there is cold air circu-
lation in the appliance.
1. Remove the screw
from the lamp cov-
er.
2. Remove the lamp
cover (refer to the
illustration).
3. Replace the used
lamp with a new
lamp of the same
Solution