I/O connector (common)
Pin
Signal
IN/OUT
No.
name
1
GND
2
START (A)
IN
3
PAUSE (A)
IN
4
START (B)
IN
5
PAUSE (B)
IN
6
RS-TRG
IN
7
GND
1 : The connection of this pin is prohibited for 1-channel
models.
2 : The connection of this pin is prohibited except in RS-
232C models.
Go/No Go output
High : displayed value > upper limit
Go : upper limit
displayed value
Low : lower limit > displayed value
Note
All Go/No Go outputs are "H" (OFF) when an alarm is set.
24
(E)
Signal
Start/latch input (A)
Pause input (A)
∗ 1
Start/latch input (B)
∗ 1
Pause input (B)
RS-232C data output/trigger input
→ "L" (ON)
lower limit → "L" (ON)
→ "L" (ON)
Start/latch input
• The "L" (ON) signal sets the maximum, minimum, and
peak-to-peak values to the current value and restarts
their storing. (Start function)
• If, when the initial setting of
of shipping is changed to
serves as the measuring mode, the "L" (ON) signal will
hold the Go/No Go output (I/O connector) and display.
(Latch function)
Note
∗ 2
While the Go/No Go output is at the "L" level, reset/preset
value recall cannot be effected by reset key or external
reset/preset value recall input.
Reset input
"L" (ON) sets the measured value to zero.
When there is a preset value this is recalled.
Note
Even when the "L" level is held, the Go/No Go output (I/O
connector) and the display are not held.