5-3. Lathe Function Settings
5-3-1. When Power is Turned On for the First Time after Factory Shipping
(LH71A lathe function and LH72)
Power ON
Basic
settings
Approx.
2 seconds
Model
(GENERAL)
Addition
display
(2)
Destination
country
(STD)
Measuring
unit
resolution
(1)
or
Detailed
settings
Display
resolution
(Measuring unit
resolution)
Scaling
(1.000000)
Compensation
value
(OFF)
Flicker control
(2)
Sleep
(OFF)
or
Start of operation
* When the segmented error compensation value is set,
the unit switches to reference point acquisition mode.
LH71A / LH72
* The setting in parentheses ( ) is the factory setting.
*
indicates the process when the setting does not be changed.
1
Use
to select
2
Use
to select the settings for display 2
3
Use
to select setting content
4
Select axis
Use
to select setting content
Performed for each axis.
Use
Note 1
5
Select axis
Use
and
Performed for each axis.
(Note)
Use at
6
Enter the setting value
7
Use
to select the setting (compensation), and then set each option
Select axis
8
Use
to select setting content
9
Use
to select setting content
(When the display resolution is 0.001 mm)
to expand the selection option.
Note 1: Use
to select setting content
Enter the compensation value
Enter the
Enter the
compensation value
position
is displayed,
1 Select LATHE
2 2/3/2ADD3/
or
3 STD/US/JPN
4 0.1/0.5/1/5/10/
to return
to
.
5 Setting at 4 or
6 0.100000 -
7 OFF/LIN Err/
or
8 OFF/1/2
9 OFF/1/5/10/30/
5. Settings
(LH71A only)
* The LH72 does
not have a
model setting.
2ADD–3/
–2ADD3/
–2ADD–3
* See Part 5-4,
"Verifying Count
Values during
Addition
Display".
00.00.01/
00.00.10/
00.01.00/
00.10.00
<Expanded>
0.05/2/20/25/
50/100/
01.00.00
higher/Diameter
display at 4
(except for
angle)/Polarity
* The X-axis
polarity should
be set so that
the value of the
cutting direction
decreases when
using diameter
display.
9.999999
SEG Err
* See Part 5-5,
"Compensation".
60
5-7
(E)