Operation; Cooker Hood - FALMEC Quantum Gebrauchsanweisung

Vorschau ausblenden Andere Handbücher für Quantum:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 24
No communica-
.
tion between UI
and induction
module
Main power
.
disturbance
Non assignable
.
failure
Fan failure
.
Defect ive tempe-
.
rature probe on
inductor
Hardware defect
.
of induction
module
Configuration
.
failure
Fixed sensor va-
.
lue (test function
for T probe on
inductor)
No fun-
Overvoltage on
ctionality
the switch mode
and no
power supply (no
displaying
functionality)
Note:
Not each failure can be delected automatically by the system, e.g. in case of
defect of the User interface power supply.

COOKER HOOD

FUMES DISCHARGE
EXTERNAL EXHAUST HOOD (SUCTION)
In this version the fumes and vapours are discharged outside
through the exhaust pipe.
To this end, the hood outlet fitting must be connected via a
pipe, to an external output.
The outlet pipe must have:
a diameter not less than that of the hood fitting.
a slight slope downwards (drop) in the horizontal sections to prevent con-
densation from flowing back into the motor.
the minimum required number of bends.
the minimum required length to avoid vibrations and reduce the suction
performance of the hood.
You are required to insulate the pipes if it passes through cold environ-
ments.
In the presence of motors with 800m
to prevent external air flowing back.
Deviation for Germany:
when the kitchen hood is used at the same time as appliances that are powered by
energy other than electricity, the negative pressure in the room must not exceed 4 Pa
(4 x 10-5 bar).
No power sup-
Check power and
ply of induction
LIN connections. If
module.
connection is OK,
Bad cabling or
replace the module
defect
1. Failure in
Check main power
main power
voltage and frequen-
frequency
cy, if ok replace the
detection
module
2. Overvoltage
Replace module or
User interface
Fan or control
Replace the module
electronic is
defect
Sensor signal
Replace the module
out of valid
range; sensor
or electronic is
defect
Defect har-
Replace the module
dware device
detected by the
self-check of the
module
2 cooking zones
Delete the actual
are delicated to
configuration
the same ele-
manual configura-
ment of the UI
tion with service
menu
Not enough
System must cool
temperature
down
change (10 K)
within 5 min
after switch on
the hob
400 V con-
Disconnect and
nection
correct the power
line connection
3
/h or higher, a check valve is present
HOOD WITH INTERNAL RECIRCULATION (FILTERING)
In this model, the air passes through the Carbon-Zeo (option-
al) filters to be purified and recycled in the environment.
Ensure that the Carbon-Zeo filters are assembled into the
hood, if not, install them as indicated in the assembly instruc-
tions.
ASSEMBLY INSTRUCTIONS
only intended for qualified personnel
The hood can be installed in various configurations.
The generic assembly steps apply to all installations; for each case,
follow the specific steps provided for the required installation.

OPERATION

WHEN TO TURN ON THE HOOD?
Switch on the hood at least one minute before starting to cook to direct fumes
and vapours towards the suction surface.
After cooking, leave the hood operating until complete extraction of all vapours
and odours. By means of the Timer function, it is possible to set auto switch-off
function which will allow the hood to turn off automatically after 15 minutes of
operation.
WHICH SPEED IS TO BE SELECTED?
speed (1-3): maintains the circulation of clean air with low electricity consump-
tion.
speed (4-5): normal conditions of use.
speed (6-7): presence of strong odours and vapours.
speed (8-P): rapid disposal of odours and vapours.
WHEN SHOULD THE FILTERS BE WASHED OR REPLACED?
The metal filters must be cleaned every 30 hours of operation.
The active carbon filters must be replaced every 18 months and replaced every
3 years.
For further details see the "MAINTENANCE" chap.
TOUCH PUSHBUTTON PANEL
ON/OFF
Short pulse: Hood switch ON/OFF
Long pulse: Hood operation automatic cycle activation (A) accor-
ding to plate power.
Speed increase from 1 to...9 (up to "P").
Speed "P": active only for a few minutes, then speed 9.
Speed decrease from P to 1.
With hood active (short pulse): TIMER (flashing red LED)
Automatic switch-off after 15 min.
The function is disabled (red LED OFF) if:
- The motor is switched off (button
- Press the TIMER button
With the hood OFF (long pulse 4s):
opening the fins for hood and metal filter maintenance
FAT METAL FILTER ALARM
Maintenance after about 30 hours' use.
Press button
22
).
again .
for 5 seconds to reset the counter.