[9][4] Calibration
Sets the background noise level for the sounder receiver.
To set the receiver of the sounder
1.
In the programming menu, press [9] to access the Siren menu.
2.
In the Siren menu, press [4] to calibrate the receiver.
3.
Select the corresponding sounder ID number.
4.
To calibrate the receiver automatically, press
confirm your input. The system now calibrates the receiver and
displays the value.
5.
To confirm the displayed value, press Enter [#].
[9][5] Tamper Mute
This function is important if you want to open a read in sounder without triggering a
tamper alarm. Activate this menu option once. The sounder tamper is then
deactivated. You can now open the cases of all sounder without triggering a tamper
alarm. Make sure you close the case before exiting the programming menu.
When you exit the programming menu, the sounder tamper contact is monitored
again.
IMPORTANT:
A tamper alarm that was already triggered cannot be stopped by this action.
[1][1][9] Acc. SV time
Timers
Quick-Key
Menu option
[1][1][9] Accessory Supervision Time
Defines the monitoring time for accessories such as interior and
exterior wired sounders. To avoid false alarms, make sure that the
monitoring time of the receiver is longer than the monitoring time for
accessories.
IMPORTANT:
To avoid false alarms, make sure that the monitoring time of the
receiver (menu option [1][3][3]) is longer than the supervision time for
accessories.
20
and select Y. Then
Default
Selection
058
00-255 minutes