The other menu pages vary with the associated functions and are described later by type of indication or setting.
In any menu at the bottom of the page there is a status bar with the main operating parameters (status, speed and pressure).
Identifying code
GO
SB
Disabled
rpm
bar
FAULT

7.4 Blocking parameter setting by Password

The device has a password-enabled protection system. If a password is set, the parameters of the device will be accessible and visible but it will
not be possible to change them. The password management system is in the "technical assistance" menu and is managed by means of the
parameter PW.

7.5 Enabling and disabling the motor

In normal operating conditions, pressing and then releasing both the "^" and "˅" keys causes the blocking/release of the motor (self-holding
even after switching off). If there is a fault alarm, the operation described above resets the alarm.
When the motor is disabled this status is shown by the blinking white LED.
This command can be activated from any menu page except RF and PW.

8. MEANING OF THE INDIVIDUAL PARAMETERS

8.1 User Menu

From the main menu, pressing the MODE key (or using the selection menu and pressing ^ or ˅ ), gives access to the USER MENU. In the
menu the MODE key allows you to scroll through the various menu pages. The values shown are the following.
Motor status manually disabled
Float function status / alarm
System disable function status / alarm
Low pressure signal function status / alarm
Operating status with auxiliary setpoint 1
Operating status with auxiliary setpoint 2
Operating status with auxiliary setpoint 3
Operating status with auxiliary setpoint 4
Operating status in multi-pump communication with the address indicated
Error status of communication in the multi-pump system
Writing and reading the factory settings on EEprom
Warning due to lack of supply voltage
Table 7 Status and error messages on the main page
Indications on the status bar at the bottom of each page
Description
Motor running
Motor stopped
Motor status manually disabled
Motor revs per minute
Plant pressure
Presence of an error preventing operation of the electropump
Table 8 Indications on the status bar
ENGLISH