CRX
7.7
Connecting the refrigerator to AC voltage
D
DANGER! mortal danger
• Never handle plugs and switches with wet hands or if you are stand-
ing on a wet surface.
• If you are operating your refrigerator on board a boat with an
AC mains connection using a shore connection, you must install a
residual current circuit breaker between the AC mains supply and
the refrigerator.
Seek advice from a trained technician.
CRX50ACDC, CRX65ACDC, CRX80ACDC, CRX110ACDC, CRX140ACDC
Proceed as follows when you connect the refrigerator to the AC supply:
➤ Plug the connector into the AC socket (fig. f 1, page 11).
CRX50DC, CRX65DC, CRX80DC, CRX110DC
You can connect the refrigerator to 100 – 240 Vw AC power if you use the MPS35
rectifier (accessory).
The MPS35 rectifier features a priority circuit which conserves the battery con-
nected. When a 100 – 240 Vw mains connection is used, the rectifier automatically
switches from battery to mains operation.
When disconnected from the 100 – 240 Vw mains supply, the rectifier automatically
switches back to battery operation. Mains operation via the rectifier always takes pri-
ority over battery operation.
Proceed as follows when you connect the refrigerator to the AC supply:
➤ Attach the rectifier on the back of the refrigerator.
➤ Connect the rectifier as shown in fig. g, page 11.
➤ Connect the refrigerator to the rectifier (fig. g 2, page 11):
– Red cable: positive battery terminal
– Black cable: negative battery terminal
➤ Plug the connector into the AC socket (fig. g 1, page 11).
EN
Installing and connecting the refrigerator
25