HPT 1000 CAN
6 Parameterisation
For the commissioning of the sensor an electronic device description file is necessary, known
as "IODD" (IO Device Description)
The EDS file and its corresponding protocol description can be downloaded from our internet
site using the path:
→Products→Sensors→Product finder
http://www.hydac.com/uk-en/products/sensors/show/Material/index.html
Entering the part number (9xxxxx) the corresponding ZIP file appears, containing the EDS
files and their respective protocol description.
6.1 Parameterisation with HYDAC portable measuring unit HMG 4000
Connect the CAN sensor to HMG 4000 using standard cable via the red socket "CAN" (K)
without external terminating resistor.
After import of the EDS file into the file manager you can configure the Node ID or the address
and Baud rate of all CANopen or J1939 devices by HYDAC ELECTRONIC GMBH by means
of the device configuration assistant.
The operation data of the CAN sensor are provided via the entries in the object directory.
More detailed information can be taken from the HMG 4000 operation manual
Edition: 2020-05-08
HYDAC ELECTRONIC GMBH
7
E
Part no.: 670023