14. PUTTING INTO OPERATION

If the cabinet has been sharply tilted while being sited or for mounting of accessories, it must be left to
stand for at least three hours before being started to allow the lubricating oil to settle in the compressor.
Failure to do so can cause total destruction of the compressor refrigerating system.
Check that the voltage on the identification plate is the same as that of the network.
THE ELECTRICAL SUPPLY LINE TO WHICH THE REFRIGERATOR WILL HAVE
TO BE CONNECTED IS TO BE PROTECTED BY A VERY SENSITIVE
DIFFERENTIAL SWITCH (Rc=16A,Dc=30mA); IT IS ALSO TO
BE LINKED TO THE GENERAL EARTHING PLANT.
Earthing is necessary and compulsory by law.
Absolutely never use reduction units, patch cords, adapters or
multiple socket outlets to connect the counter.
DIRECTLY connect the equipment to the mains.
The cable should be fully extended and located where it is unilikely to
be struck, caught or stepped on, away from water and the other liquids
and heat sources and must not be damaged.
In case of breakage of the power cable of the cabinet, it must be replaced by the manufacturer
or by instruction it change of it.
Follow the manufacturer's instructions to install the unit, using qualified personnel and complying with
the electrical regulations for the specific country.
Incorrect installation may cause injury and damage; the manufacturer is not liable for this.
The manufacturer disclaims all responsability for any damage to people or things due to
incorrect observance of this rule.

15. MAINTENANCE

WARNING! Maintenance must be carried out by technical staff trained and enabled for intervention on the
flammable refrigerants.
WARNING! Any work carried out on the appliance by the user strictly requires the power plug being
disconnected from the mains socket.
ATTENTION! Use protective shoes and gloves during maintenance operations.
OPERATION
Cleaning the outer surface
Cleaning the accessible inner parts
Checking the power supply, electrical plugs and/or sockets
Seals intactness check
Check the acceptable condition of warning plates
Water collection tank cleaning
Fridge system tubing intactness check
Inspecting the cables and inner power connections
Replacing the led lights
Replacing the power supply cable
Control panel replacement (electronic control unit)
Any other maintenance operation not planned in the previous points should be carried out by the
support centres authorised by our dealers or by qualified staff.
DELIGHT LITE
DELIGHT PRIME
EPTA S.p.A. - Sede legale
Via Mecenate, 86 - 20138 Milano – Italy
Capitale € 68.515.000 - R.E.A./MI – 1730229
Registro delle Imprese e Cod.Fiscale n. 04160730968
Partita IVA 04160730968
(do not use tools)
ORDINARY /
FREQUENCY
EXTRAORDINARY
MAINTENANCE
Based on use
Ordinary
Based on use
Ordinary
Six-monthly
Ordinary
Six-monthly
Ordinary
Six-monthly
Ordinary
Based on use
Ordinary
Six-monthly
Ordinary
Six-monthly
Ordinary
-
Extraordinary
-
Extraordinary
-
Extraordinary
1 8 / 6 8
PAGE
UM000327
N° DOC
AUTHORISED
STAFF
User
User
User
User
User
Technical support
Technical support
Technical support
Technical support
Technical support
Technical support

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis