6.2 Housing opening
Unscrew the screws (01) on the rear flange (02) using
the hexagonal wrench (03) provided.
02
Fig. 2
Slide out the rear cover plate of the housing, taking
care to leave the sealing washer in its seating.
Fig. 3
6.3 How to install the camera
Electrical connections must be performed
with the power supply disconnected and
the circuit-breaker open.
When commencing installation make sure
that the specifications for the power supply
for the installation correspond with those
required by the device.
Do not power the product using auto-
transformers.
Check that the power supply socket and
cable are adequately dimensioned.
Nominal section of the cables used: consult
the technical data in the relevant chapter (
12 Technical data, page 15).
10
The power cables must be sized according to the
ratio between the supply current and the distance to
be covered.
Open the housing as described in the relative chapter
(6.2 Housing opening, page 10).
01
03
Assemble the camera on the slide using the
insulating spacer (01) and the 1/4" screw and the
washer (02) provided. If necessary, use the spacers to
position the camera and lens correctly.
Fig. 4
Insert the cables through the cable glands and
electrically connect.
Ensure the cable glands are firmly fastened.
6.3.1 12Vdc/24Vac version
When the power supply voltage is 12Vdc/24Vac the
circuit will be connected by the terminals shown.
OUT 12Vdc/24Vac
Fig. 5
01
Nominal section of the cables used: from
0.2mm² (24AWG) up to 2.5mm² (13AWG).
IN 12Vdc/24Vac
Heater OUT 12Vdc/24Vac
02
MNVCNXM36_2051_EN