9. Problem-solving by the installer

Baking out of the heating rods
Moisture can accumulate in the heating rods in humid ambient conditions or dur-
ing long periods of non-use. This is a physical process and not a manufacturing
fault. Under certain circumstances, accumulation of moisture in the heating rods
can lead to the FI circuit breaker being triggered.
In this case, it is necessary to bake out the sauna heater under the supervision
of an electrician. To do this, the protective function of the FI circuit breaker must
be switched off. The baking out procedure takes approximately 10 minutes.
The safety function of the FI circuit breaker must subsequently be reactivated.
If the problem persists, consult your supplier.
Resetting the overheat cut-out of the evaporator
The temperature switch 2 is responsible for the water
shortage detection function.
If a certain water level in the evaporator tank is not
complied with (approx. 1 l), this temperature switch
EN
switches off the heating element. At the same time,
the feedback to the WM control unit falls to 0 V –
the control unit displays the message "FILL".
The temperature cut-out 1 is used as protection against
overheating. This cut-out must be reset manually. To do
so, press the protruding metal contact in the middle of
the temperature cut-out
1
1 temperature cut-out 150 °C (no automatic reset)
2 automatic reset temperature switch 110 °C
2