CONTROLLER OPERATION

LED Display
Heater Button
Bubble Button
- Adjust the bubble level by pressing
the button (L1: 300W, L2: 500W, L3: 720W
Up Button
UVC Button
LED display
°C
°F
Once powered-up, press the RESET on the PRCD. The LED displays the current water temperature automatically.
NOTE: The actual water temperature may vary from the temperature displayed on the LED screen by as much as approximately 1°C.
JET Button
Press the
JET button to turn the water jet massage function on and off. The light above the JET button displays green when activated.
NOTE: The BUBBLE button can only be adjusted to L1 or L2 when the JET system is activated.
NOTE: The JET system will shut off automatically after one hour.
Adjust the jet nozzles (a) to change the water stream directions.
Turn the jet control knob (b) to change the water stream setting.
HEATING
HEATER button to turn the heating system on/off. When the light above the heat button is red, the heating system is activated.
1. Press the
HEATER
HEATER
°C
When the light is green, the water is at the set temperature and the heating system is at rest.
20-40
2. Pressing the
UP or
UP
ture setting (from 20°C to 40°C ). The new and desired temperature setting will remain on the LED display for 3 seconds to confirm the new value.
NOTE: The default temperature is 38°C.
NOTE: If the heating system is turned on, the filtration system will automatically start.
NOTE: When the water temperature is below 1°C (33.8°F), the anti-icing system will be activated automatically to heat the water to 3°C (37.4°F).
IMPORTANT: The following conditions will lead to slow water heating
An ambient temperature lower than 10°C (50°F).
An outdoor wind speed above 3.5-5.4m/s (8-12mph).
If the air bubble function is activated when the heater is on.
If the spa cover is not properly in place when the heater is on.
Jet Operation
DOWN button will cause the LED to flash. When it is flashing you can adjust the water to the desired tempera-