AHT Cooling Systems GmbH | en
Replace batteries
Observe the separate instructions for battery replace-
ment (safe removal and replacement).
These instructions are available to the qualified staff.
Battery type
– According to instructions for changing the battery
Battery replacement control
If error code E11 is displayed Alarm contact the main-
tenance service immediately [see } Chapter 11.2.5].
For the sake of completeness of data (date, time), an
uninterruptible power supply through the use of this
built-in battery is required.
11.2.4 What to do if ...
All appliances are carefully tested for performance and
safety at the AHT test centre.
a) Immediate contact the maintenance service
[see } Chapter 11.2.5] in the event of:
– malfunction [see } Chapter 10.3]
– loud noises or vibration
– failure of the control and display elements
[see } Chapter 5].
b) Provide the following information:
– Appliance type
– 14-digit serial number of the appliance
– See rating plate [see } Chapter 3.2.1]
– Additional sticker on the appliance
Fig. 20: Example of 14-digit serial number
– Type of malfunction
c) Make the defective appliance inaccessible to end
customers.
11.2.5 Maintenance services
If you have any questions regarding maintenance
(maintenance, service, repair, etc.), please contact the
AHT service partner in your region:
Service line (tele-
See sticker on the appliance
phone)
Email
product_support@aht.at
Technical support
Email
spare_parts@aht.at
Ordering of spare
parts
AHT online spare
https://catalog.aht.at
parts catalogue
8 years after the last unit of the
Availability of legally
model has been put into circula-
required spare parts
tion
440031_1_0321
Minimum duration of
–
warranty
Legally required in-
formation about the
https://eprel.ec.europa.eu/
model
Online contact
www.aht.at/services
QR code www.aht.at/services
The maintenance services have access to all neces-
sary and current information for commissioning and
maintenance, e.g.
– spare parts lists
12
Disassembly, disposal
WARNING
Leakage or residue of flammable refri-
gerant.
Flammable refrigerant can cause an explosive
gas/air mixture. Fire hazard.
§ Do not damage pipes.
§ Prior to dismantling and disposal, open
the refrigerant circuit properly and suck off
the refrigerant safely and completely. No
residues may remain in the refrigerant cir-
cuit.
§ Only qualified staff may suck off the refri-
gerant.
CAUTION
Improper disposal.
Environmental damage.
§ Dispose of components in a professional
and environmentally friendly manner, e.g:
- Refrigerant
- Insulating foam (pentane)
- Compressor oil
- Batteries
- Film and packaging
- Glass
§ Separate collection of electrical and elec-
tronic equipment according to the valid na-
tional disposal regulations (e.g. WEEE
within the EU) and the regulations of the
local disposal partner.
§ Dispose of batteries correctly according
to local and national disposal regulations.
§ Do not dispose of the appliance with
household waste.
Disassembly, disposal | 12