28/32 Technical data
Table 6: Troubleshooting
Problem
LED1 flashes at 5Hz
(duty cycle 50%)
LED1+2+3+4+5
flash at 5Hz (duty
cycle 50%)
Technical data
10
Table 7: General information on the battery pack
Designation
Part number
Nominal voltage [V]
Nominal capacity [Ah]
Dimensions [mm]
Nominal power [Wh]
Weight [g]
Battery type
Storage temperature
Operating temperature
Bosch Rexroth AG, NX-BP2-36V, NX-BC36V, NX-BC36V-CN, 3608870DP0, AA/05.2017
Possible cause
There is
•
overtemperature
during charging (TCA)
There is cell overvoltage
•
(COV)
There is overcurrent
•
during charging (OCC)
The charging timer
•
(capacity limitation) has
been exceeded
The temperature at the
•
internal heat sink is <0°
C or >100°
The fan does not reach
•
the required speed
Measure
During charging, the follo-
•
wing must not be at hand:
Overtemperature
Cell overvoltage
Overcurrent
Exceedance of the capacity
limitation
Remove the battery and
•
check the battery charger
using different batteries.
•
Separate the battery charger
•
from the mains, plug it in
again and repeat the check.
Separate the battery charger
from the mains, plug it in again
and repeat the check.
NX-BP2-36V
0.608.843.019
36 V
2.6 Ah
137.5 x 82.3 x 68 mm
93.60 Wh
750 g
Lithium ions (Li-Ion)
-20°C bis +45°C
0°C bis +45°C