Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

28/32 Technical data

Table 6: Troubleshooting
Problem
LED1 flashes at 5Hz
(duty cycle 50%)
LED1+2+3+4+5
flash at 5Hz (duty
cycle 50%)
Technical data
10
Table 7: General information on the battery pack
Designation
Part number
Nominal voltage [V]
Nominal capacity [Ah]
Dimensions [mm]
Nominal power [Wh]
Weight [g]
Battery type
Storage temperature
Operating temperature
Bosch Rexroth AG, NX-BP2-36V, NX-BC36V, NX-BC36V-CN, 3608870DP0, AA/05.2017
Possible cause
There is
overtemperature
during charging (TCA)
There is cell overvoltage
(COV)
There is overcurrent
during charging (OCC)
The charging timer
(capacity limitation) has
been exceeded
The temperature at the
internal heat sink is <0°
C or >100°
The fan does not reach
the required speed
Measure
During charging, the follo-
wing must not be at hand:
Overtemperature
Cell overvoltage
Overcurrent
Exceedance of the capacity
limitation
Remove the battery and
check the battery charger
using different batteries.
Separate the battery charger
from the mains, plug it in
again and repeat the check.
Separate the battery charger
from the mains, plug it in again
and repeat the check.
NX-BP2-36V
0.608.843.019
36 V
2.6 Ah
137.5 x 82.3 x 68 mm
93.60 Wh
750 g
Lithium ions (Li-Ion)
-20°C bis +45°C
0°C bis +45°C

Werbung

Kapitel

Inhaltsverzeichnis
loading

Verwandte Produkte für REXROTH NX-BP2-36V

Diese Anleitung auch für:

Nx-bc36vNx-bc36v-cn

Inhaltsverzeichnis