Important
The connection must be made by authorised,
skilled personnel, in accordance with the re-
levant legal requirements, using appropria-
te and specified materials. The appliance is
supplied with operating voltage 400V3~N
, which can be switched to 230V3~ (on re-
quest).
For direct connection to the mains one must en-
visage a device that ensures disconnection from
the mains, with a contacts opening distance
that ensures complete disconnection in the con-
ditions of category III over-tension, in complian-
ce with the installation rules.
Caution - Warning
Before doing any work, cut off the mains
electricity supply.
Connect the appliance to the mains electricity
supply as follows:
If not already present, install a circuit-breaker
1)
close to the appliance, with the following
(A)
characteristics:
– Thermal breaker device (to adjust see table An-
nexes).
GB
E
F
3320120_inst_GB

ELECTRICAL CONNECTION

B
D
D
G
– Magnetic circuit breaker curve B (IEC 60898-1).
– Residual current protection set at mA 30.
Pull off the knob (B).
2)
Remove the drip tray (C) .
3)
Undo the screws (D) and remove the control
4)
panel (E).
Take out screw (F) to move the protection (G).
5)
Connect the circuit-breaker (A) to the terminal
6)
board (H) as shown in the diagram and in the
electrical system diagram at the back of the
manual and using a cable with the following:
– Weight: ≥ than H05RN-F type (designation 245
IEC 57).
Temperature of use: ≥ 70°C.
Important
When connecting, take care to connect the
phase and neutral lines.
Tighten the cable gland (L).
7)
Move the protection back forwards (G) and
8)
lock it by the screw (F).
Replace all when the operation is complete.
9)
C
L
H
- 8 -