INSTALLATION

CLEANING, CARE AND MAINTENANCE

4.6

Taking the appliance out of use

Disconnect the appliance from the power supply using the isola-
»
tor in your electrical installation (e.g. MCB).
5.
Cleaning, care and maintenance
If a pale brownish discolouration appears on the appliance cas-
ing, wipe this off as soon as possible with a damp cloth. Clean
the appliance when cold with ordinary cleaning products. Avoid
abrasive or corrosive cleaning products.
CAUTION Fire
Never spray cleaning spray into the air slot.
Ensure that no moisture can enter the appliance.
As part of regular maintenance, we recommend also having the
control components checked. The safety and control components
should be checked by a contractor no more than ten years after
commissioning.
6.

What to do if ...

... the appliance does not heat up:
Check the temperature set at the appliance and the MCB/fuse in
your fuse box.
The appliance has a safety temperature controller that shuts the
appliance down if it overheats. After the cause has been removed
(for example air outlet or inlet apertures covered) and the appli-
ance has cooled down for a few minutes, operation starts again.
If you cannot remedy the fault, contact your contractor. To facilitate
and speed up your enquiry, please provide the number on the type
plate (no. XXXXXX - XXXX - XXXXXX).
7.

Safety

Only qualified contractors should carry out installation, commis-
sioning, maintenance and repair of the appliance.
7.1

General safety instructions

We guarantee trouble-free operation and operational reliability
only if the original accessories and spare parts intended for the
appliance are used.
DANGER Electrocution
If you mount the appliance on the wall, do so in such
a way that control equipment cannot be touched by a
person in the bath or shower.
CAUTION
!
— Only fit the wall mounted appliance to a vertical
wall that is temperature-resistant to at least 85 °C.
— Observe the minimum clearances to adjacent ob-
ject surfaces.
— Never install the appliance directly below a wall
socket.
— Ensure that the power cable is not in contact with
any appliance components.
16
|CNS UT
7.2

Instructions, standards and regulations

Observe all national and regional regulations and in-
structions regarding installation, assembly and com-
missioning.
8.

Appliance description

8.1

Standard delivery

— Wall mounting bracket (hooked into the appliance)
9.

Mounting

9.1

Minimum clearances

≥100
9.2

Installing the wall mounting bracket

You can also use the wall mounting bracket as a template for wall
mounting; this ensures the required floor clearance.
Unhook the wall mounting bracket.
»
Place the centred wall mounting bracket level on the ground and
»
mark holes 1 and 2.
Lift up the wall mounting bracket so that its lower holes match
»
up with the markings you have just made on the installation wall.
Mark holes 3 and 4 on the installation wall.
»
1
2
a a a
≥100
≥500
≥20
3
4
WWW.STIEBEL-ELTRON.COM