40. Clear low starter voltage alarm - 702 and -712 only
When the auxiliary voltage rises above this value, the alarm is switched off. This value
needs to be greater than or equal to the previous parameter.
41. High starter voltage alarm - 702 and -712 only
When the auxiliary (e.g. starter battery) voltage rises above this value for more than
10 seconds, the alarm will be activated. This is a visual and audible alarm. It does not
energize the relay.
42. Clear high starter voltage alarm - 702 and -712 only
When the auxiliary voltage falls below this value, the alarm is switched off. This value needs
to be less than or equal to the previous parameter.
Default
0 V
_______________________________________________________________
43. High temperature alarm - 702 and -712 only
When the battery temperature rises above this value for more than 10 seconds, the alarm
will be activated. This is a visual and audible alarm. It does not energize the relay.
44. Clear high temperature alarm - 702 and -712 only
When the temperature falls below this value, the alarm is switched off. This value needs to
be less than or equal to the previous parameter.
45. Low temperature alarm - 702 and -712 only
When the temperature falls below this value for more than 10 seconds, the alarm will be
activated. This is a visual and audible alarm. It does not energize the relay.
46. Clear low temperature alarm - 702 and -712 only
When the temperature rises above this value, the alarm is switched off. This value needs to
be greater than or equal to the previous parameter.
See parameter 67 for choosing between °C and °F.
Default
0°C
0°F
Range
0 – 95 V
Range
-99 – 99°C
-146 – 210°F
Step size
0,1 V
Step size
1°C
1°F