4
HPR PAC
D
Dry Cutting System
CONTROL BOARD
041993
J106
S101
ON
1 2
C
1 2 3 4
S100
J303
ON
1
2
3
4
1
1 2 3 4 5 6 7 8
Serial ID
Machine Motion
Dipswitch
Jumper Block
J300B
J300A
B
Notes:
1) For a single system installation set Serial ID (S100),
Machine Motion (J303), J106 & J107 as shown above.
2) For a two system installation duplicate a second power supply and Command THC
as illustrated for a single system, set Serial ID as shown for the second system.
3) For a three system installation set up as described above, set Serial ID as shown
for the third system.
4) For a four system installation set up as described above, set Serial ID as shown
for the fourth system.
5) All machine interface cables (Pwr. supply-CNC) used for serial communication between
A
Pwr. supply-CNC will have a common connection node with the CNC.
6) The CNC will need a dedicated I/O port for each Command THC.
7) If a Hypertherm Automation controller is being used, and there are intermittent communication
failures (PS Link Failure), try removing the jumpers on J106 and J107 on the control board,
and the termination jumper (J6 or J8) on the serial isolation board in the controler.
Only remove the termination jumper on the serial isolation board that is connected
to the HPR power supply. See figure on Sheet 19 for details.
4
7-22
3
Optional Command THC Interface
041842
J107
PLASMA INTERFACE
BOARD
1 2
CNC Interface Cable
2 3 4
See Command
THC Manual for
internal Power
Supply wiring
J2B
CNC Interface Cable
CNC Interface Cable
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
3
2
Pendant Ext. Cable
Command
THC
Lifter I/O Interface Cable
(Optional Unit)
Motor Drive Cable
CNC Interface Cable
Command I/O Cable-Second THC
Command I/O Cable-Third THC
Command I/O Cable-Fourth THC
CNC
Interface
(Customer Supplied)
S100
Serial ID
Dipswitch
for second system
S100
Serial ID
Dipswitch
for third system
S100
Serial ID
Dipswitch
for fourth system
2
1
(Optional Unit)
Torch
Operator
Pendant
Workpiece
(Optional Unit)
Dipswitch setting example:
S100
ON
1 2
3 4 5 6 7 8
Switch 1 is in the On position
Switches 2-8 are in the Off position
ELEC SCH:HPR260XD POWER SUPPLY
013377
SHEET 18 OF 19
1
Torch
D
Lifter
C
B
A
E