Herunterladen Inhalt Inhalt Diese Seite drucken

Environment; Delivery Condition - Chauvin Arnoux F 65 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für F 65:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 36
Battery Low indicator
is displayed when the voltage delivered by the battery is less
than the operating voltage.
Sampling
2 measurements/s for the digital display, 100 ms for the MAX function.
Degree of protection of the enclosure
IP 30 as per NF EN 60529
Maximum opening of jaws
Ø 28 mm
Dimensions
(L x l x H) : 218 x 64 x 30 mm
Weight
280 g (with batteries)

5.3. ENVIRONMENT

5.3.1. TEMPERATURE
Operation: 0°C to 40°C, < 80 % RH
Storage: -10°C to 60°C, < 70 % RH
5.3.2. EMC
Emissions and immunity in an industrial setting compliant with EN
61326-1

5.3.3. DELIVERY CONDITION

A Leakage Clamp-on Meter F65 delivered in a box with:
- 1 operating manual
- 1 set of measuring cords (D4 mm, one black and one red)
- 2 1.5 V AAA or LR03 batteries
- 1 carrying bag
APPENDIX: Reference conditions
Sine-wave signal:
- Frequency from 48 to 65 Hz
- No DC component
- Temperature 23°C ± 5°C, RH < 80 %
- External magnetic field < 40 A/m
- No alternating magnetic field
- Conductor being measured centred (in A)
- Specifications given for values from 5 to 100 % of each range.
Note: For a crest factor CF between 1.4 and 3 at full scale, add 1 %
to these specifications.
34