3.
Description of load limiter dynasafe
3.1.
Presentation
The load limiter dynasafe
principle of a potential-free contact which is tripped when the tension in the wire rope exceeds the
preset limit.
This load limiter is specially designed to manage one or two safety thresholds on small and medium
capacity overhead travelling cranes.
3.2.
Operating principle
The operating principle of dynasafe
body through a tangential force, which is proportional to the force exerted on the wire rope when
pulled.
When the deformation of the load limiter body is above a limit, the integrated micro-switch opens.
The contact is automatically reset once the tension in the wire rope is below the set limit increased
by a hysteresis value depending of the effort.
3.3.
Marking
See figure 1
1
2
3
4
5
6
7
8
9
10
11
12
All indications and labels affixed on the product by the manufacturer must be kept
fully legible. If any indications and labels are removed or damaged, they must be
replaced before continuing to use the product. Tractel® can supply new marking
materials on request
3.4.
Technical specifications
Installation
Repeatability
Measurement sensor
Category
Cut-out voltage
TM
Mecha 3.2 is a mechanical load limiter for wire ropes operating on the
TM
Mecha 3.2 is based on the deformation of the load limiter
Adjustment screw and locknut for threshold 1
Adjustment screw and locknut for threshold 2
Option : factory setting parameters for threshold 1
Option : factory setting parameters for threshold 2
Protection index
Microswitch interrupting capacity and voltage
Device serial number
Identification
Symbol indicating «You must read the user manual»
QR Code that contains CE certificate, present manual
Compatible wire rope diameters
Capacity on strand (working load limit)
Directly on idle strand
1% FS
2 integrated micro switches
Contact 1 : 1 NO, 1 NC
Contact 2 : 1 NO, 1 NC
1 (as EN ISO 13849-1)
250 VAC
TM
Mecha 3.2
GB
GB
DE
NL
ES
IT
PT
GR
NO
SE
FI
DK
PL
RU
7