1.2. Composition of a standard supply
minifor™
Each minifor™ (depending on model) is supplied in a
box or metal case containing:
1. The hoist with its control box, equipped with its
carrying handle, its safety hook and a power supply
cable with male/female connector.
2. A plastic bag, containing:
• a low limit stop on spring,
• a 3 mm ALLEN wrench to secure the limit stops on
the wire rope.
3. A plastic bag, containing:
• this manual,
• the CE compliance certificate,
• if necessary, the documents concerning the radio
remote control.
4. Depending on the control option, the lifting wire
rope (to the length required) mounted on a reel,
equipped with a safety hook and a high limit stop
mounted on spring.
1.3. Description and markings
On request: other voltages and frequencies.
Number of phases
WLL standard/sheaved (kg)
Speed standard/sheaved (m/min)
Classe FEM 9.511/ISO
Power (kW)
Startup current (A)
Nominal current (A)
Power supply voltage (V)
Control voltage (V)
Frequency (Hz)
Diameter of steel wire rope (mm)
Weight of wire rope per meter (kg)
Weight of standard hoist (without wire rope) (kg)
Winder weight with 20m of wire rope (kg)
Winder weight with 27m of wire rope (kg)
Winder weight with 40m of wire rope (kg)
Weight a sheaving kit (kg)
L
dB(A)
WA

3. Accessories and spare parts

The following parts and accessories can be supplied
and installed by the user:
Figure 1 shows a standard minifor™ in its most
frequently used operating position, ready for operation,
suspended on a clamp secured to a beam. The standard
hoist is supplied with a 2.5 m electric control cable
with control box (Fig. 2) and a 0.50 m electrical power
supply cable. On request, the unit can be supplied with
different control and power supply cable lengths. Each
unit carries a serial number on the top of the casing.
The complete number (including letter) must be given
whenever requesting spare parts or repairs.
Regularly check that all the labels are in place and can
be easily read.
The length of the lifting wire rope is marked on the end
sleeve in the hook. If necessary, check the wire rope
length as it is possible that the wire rope may have
been shortened since the unit was delivered. All the
minifor™ hoists are supplied with a control box (Fig. 2),
with double insulation IP 65 and 3 controls: Up, Down
and Emergency stop.
NOTE: The "Up" and "Down" controls are indicated on
the corresponding control buttons by an arrow showing
the direction of movement, with the control box held in
its hanging position (Fig. 2).

2. Functional specifications

TR10
TR30
TR30S
1~
1~
1~
100 / 200 300 / 600
300 / 600
15 / 7.5
5 / 2.5
13 / 6.5
-
-
1Bm / M3 1Bm / M3 1Bm / M3 1Bm / M3 1Bm / M3 1Bm / M3 1Bm / M3
0.25
1.1
25.5 / 17.3
54 / 16
7.5 / 3.9
16 / 8
115 / 230
115 / 230 230 / 400 115 / 230 230 / 400
115 / 230
115 / 230 230 / 400 115 / 230 230 / 400
50
50
6.5
6.5
0.17
0.17
21
33
+23
-
+28
-
+30
-
+5
+8
86
85
88
• High and low limit stops (interchangeable).
• Lifting wire rope equipped with eye hook.
• Fuse.
• Power supply connector (electrician).
TR50
3~
1~
3~
500 / 950
7 / 3.5
1.1
19 / 11
54 / 16
19 / 11
5.9 / 3.4
16 / 8
5.9 / 3.4
50
6.5
0.17
33
33
33
-
-
-
-
-
-
-
-
-
+8
90
TR55
TR110
1~
3~
1~
550 / -
550 / 1100
7 / -
7 / 3.5
1.1
1.1
54 / 16
19 / 11
16
16 / 8
5.9 / 3.4
8
230
400
230
230
400
230
50
50
6.5
6.5
0.17
0.17
33
33
43
-
-
-
-
-
-
-
-
-
-
+8
90
90
11
GB

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis