3.2.11 W
. COMPLY WITH the local water supply authority regulations.
arning
Under IEC  60335-2-79, the appliance may only be connected to the mains
drinking water supply if the supply hose is fitted with a backflow preventer valve
with drain facility corresponding to EN 12729 type BA. The backflow preventer
can be ordered from the manufacturer.
3.2.12 W
. Water that has passed through backflow preventers is considered to
arning
be non-potable.
3.2.13 W
. Maintenance and/or repair of electrical components MUST be carried
arning
out by qualified staff.
3.2.14 W
. DISCHARGE residual pressure before disconnecting the hose from the
arning
appliance.
3.2.15 W
. CHECK before each use and at regular intervals that the screws are fully
arning
tightened and that there are no broken or worn parts.
3.2.16 W
. ONLY USE detergents which will not corrode the coating materials of
arning
the high pressure hose / electric cable.
3.2.17 W
. ENSURE that all people or animals keep a minimum distance of 16 yd. (15m) away.
arning
3.2.18 W
. This appliance is designed for use with the detergent supplied or
arning
recommended by the manufacturer. The use of other detergents or chemicals
may adversely affect the appliance' s safety.
3.2.19 W
. Do not allow the detergent to come into contact with the skin, and the
arning
eyes in particular! In case of contact with eyes, rinse with plenty of water and
seek medical advice at once!
3.2.20 W
. High pressure hoses, fittings and joints are important for the appliance' s
arning
safety. Use only hoses, fittings and joints recommended by the manufacturer.
3.2.21 W
. To ensure the appliance' s safety, only use the manufacturer' s genuine
arning
parts, or other parts which carry its approval.
3.2.22 W
. Unsuitable extension cables can be dangerous. If an extension cable is
arning
used, it must be suitable for outdoor use, and the connection must be kept dry
and off the ground. Use of a power cable reel which keeps the socket at least 60
mm above the ground is strongly recommended.
3.2.23 W
. Switch the appliance off and disconnect it from the power supply before
arning
assembly, cleaning, adjustments, maintenance, storage and transportation.
3.2.24 W
. Insert the pipe jet kit down to the red mark before turning the appliance on.