Herunterladen Inhalt Inhalt Diese Seite drucken

Travel Acquisition; Before Starting - Roger Technology BH30 Serie Anweisungen Und Hinweise Für Den Installateur

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 92
11

Travel acquisition

For the system to function correctly, the barrier travel must be acquired by the controller.
11.1

Before starting:

IMPORTANT:
Select the automation system model installed with the parameter
KEY:
HIGH SPEED Motors
SELECTION
MODEL
BH30/600
BH30/800
BH30/600/HS
BM30/400
BM30/300/HS
BH30/804/R
1. Select the position of the motor relative to the gate with the parameter
with the motor installed on the right hand side of the gate (seen from interior side).
LEFT OPENING
2. Adjust the (mechanical or magnetic) limit switches so that, once triggered, the gate stops slightly before it reaches
the mechanical stop.
CLOSING LIMIT SWITCH
3. Check that the operator present function is not enabled (
OPEN
STOP
CLOSE
4. Move the gate into the closed position.
5. Press TEST (see TEST mode in chapter 10) and check the command signal and safety device states. If any safety
devices are not installed, jumper the relative contact or disable the device from the relative parameter ( ,
,
and
).
Reversible Motor
MOTOR TYPE
/
600kg
/
1000kg
600kg
see chapter 14 "Special Parameters for High Speed Motor"
/
500kg
400kg
see chapter 14 "Special Parameters for High Speed Motor"
800kg REVERSIBLE
see chapter 15 "Special Parameters for Reversible Motor"
RIGHT OPENING
OPENING LIMIT SWITCH
.
CONFIGURATION
. The default setting for this parameter is
).
,
,
71

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis