BES M12EH1-L01C40B-S04G-L04 / BES M18EH1-L01C80B-S04G-L04
Inductive sensors
3
Overview of IO-Link Data and Functions (continued)
3.2
Device Variants
The following three variants are available, which differ in
their process data profiles:
–
LSSC
–
AdSS
–
Comprehensive Condition Monitoring
The functions remain unchanged in the process. The
switching profile is influenced by a change between LSSC
and AdSS. Only one switching point is configurable in the
AdSS profile.
Variant
Device ID
Variant 1 (LSSC)
0x020404
Variant 2 (ADSS)
0x020405
1)
Variant 3 (CCM)
0x020406
Default
1)
Tab. 3-1:
Device Variants
3.3
Process Data Profiles
See section 6.7 Process Data Info and Configuration on
page 88.
Variant 1 (LSSC)
PD Input
Bit 7
Bit 6
System error
Reserved
Tab. 3-2:
Process data profile for PD Input – Variant 1 (LSSC)
PD Output
No PD-Output data available.
Variant 2 (ADSS)
PD Input
Bit 7
Bit 6
System error
Reserved
Tab. 3-3:
Process data profile for PD Input – Variant 2 (ADSS)
PD Output
No PD-Output data available.
www.balluff.com
Baud rate
PDInput
COM3 (230.4 kbits/s)
COM3 (230.4 kbits/s)
COM3 (230.4 kbits/s)
17 byte
Byte 0
Bit 5
Bit 4
Transducer
Signal Quality
out of range
Bad
Byte 0
Bit 5
Bit 4
Transducer
Signal Quality
out of range
Bad
No. of
No. of
IO-Link protocol
PDOutput
1 byte
–
1 byte
–
1 byte
Bit 3
Bit 2
Reserved
Reserved
Bit 3
Bit 2
Reserved
Reserved
Minimum
version
cycle time
1.1.2.
2 ms
1.1.2.
2 ms
1.1.2.
2 ms
Bit 1
Bit 0
SSC2
SSC1
(LSSC2)
(LSSC1)
Bit 1
Bit 0
Reserved
SSC1
(ADSS1)
english
9