Technical Data
11.6
Analog Input Modules (SCMI-600-01)
Designation
Number
Plug
Inputs
Voltage
Power supply
Interface
Housing material
Housing sealing
Type of protection
Ambient temperature
Storage temperature
11.6.1 Connections, SC Sensors
Designation
Number
Plug
Inputs
Voltage
Power supply
Fuse
Accuracy
Input signal range
Scanning rate
11.6.2 Connection, External Sensor
Designation
Number
Plug
Inputs
Voltage
Power supply
Accuracy
Input signal range
Scanning rate
268
Properties
4
3× 5-pin, ODU
1× 5-pin, M12×1
INx-1, INx-2, INx-3, INx-4, INx-5
+24 V
DC
max. 250 mA
Measuring bus based on RS-422
ABS/PC
TPE
IP65
-10 – +50 °C
-20 – +60 °C
Properties
3
5-pin, ODU
INx-1, INx-2, INx-3
+12 V
DC
max. 70 mA
Protection against overvoltage,
short-circuit protected
0.1 % FS (full scale)
-3.4 V – +3.4 V
1 ms = 1,000 measured values/s
Properties
1
5-pin, M12×1
INx-4, INx-5
+24 V
DC
Max. 100 mA
0.1 % FS (full scale)
-3.4 V – +3.4 V
1 ms = 1,000 measured value/s
(FAST MODE at 100 µs)
Description
Per network
Thermal fuse
When installed
Description
For Parker sensors
Analog
Thermal fuse
Active current monitoring for
each channel
= end value of measuring
range
Description
For sensors with current/volt-
age output
Analog
Per network
Thermal fuse
= end value of measuring range
The Parker Service Master CONNECT V1.0/04/20