Design and Function
3.3.1

Parker CAN / External CAN

You can use the CAN X and CAN Y ports to connect the device via
CAN BUS lines and additional Y-junctions to up to 24 Parker sensors
(max. 24 channels ) with automatic sensor detection
(Parker CAN).
Fig. 4
Connection port, CAN X / CAN Y
PIN Designation
1
Shielding
2
+Ub (+24 V
3
GND
4
CAN High
5
CAN Low
INFORMATION
The CAN X and CAN Y ports are not galvanically separated. A gal-
vanic separation is only provided in SAEJ1939-IM.