Parts and Functions
"HOT KEEP" function
"HOT KEEP" is operated in the following cases.
y When heating is started:
In order to prevent blowing out of cool wind, the indoor unit fan stopped according to the room temperature which heating
operation is started. Wait for approx. 2 to 3 minute, and the operation will be automatically changed to the ordinary heating
mode.
y Defrosting operation (in the heating mode):
When it is liable to frost, the heating operation is stopped automatically for 5 to 12 minutes once per approx. one hour, and
defrosting is operated. After defrosting is completed, operation mode is automatically changed to ordinary heating operation.
y When the room thermostat is actuated:
When room temperature increases and room temperature controller actuates, the fan speed is automatically changed to stop
under low temperature condition of indoor heat exchanger. When room temperature decreases, air conditioner automatically
changes over to ordinary heating operation.
Warming operation
y Heat pump type warming
With the heat pump type warming, the mechanism of heat pump that concentrate heat of outdoor air with the help of refrigerant
to warm the indoor space, is utilized.
y Defrosting operation
When a room is warmed with a heat pump type air conditioner, frost accumulates on the heat exchanger of outdoor unit along
with the drop of indoor temperature. Since the accumulated frost reduces the effect of warming, it is necessery to automatically
switch the operation to the defrosting mode. During the defrosting operation, heating operation is interrupted.
y Atmospheric temperature and warming capacity
Warming capacity of heat pump type air conditioner decreases along with the drop of outdoor temperature. When the warming
capacity is not sufficient, it is recommended to use another heating implement.
y Period of warm-up
Since the heat pump type air conditioner employs a method to circulate warm winds to warm the
entire space of a room, it takes time before the room temperature rises.
It is recommendable to start the operation a little earlier in a very cold morning.

Maintenance

Clean the air filter
1. Pull the filters upward to remove them from the Intake Grill.
2. Clean the air filter: Remove the dust from the filters by vacuum cleaner or washing them.
After washing, allow the air filters to dry thoroughly in an area protected from sunlight.
3. Re-attach the air filters to the Intake Grill. Press the two buttons on the filters until you hear
a sound of click.
Maintenace of indoor units
y When used for extended periods, the unit may accumulate dirt inside, which reduces its performance. We recommend that
the unit is inspected regularly, in addition to your own cleaning and care. For more information, consult authorized service
personnel.
y When cleaning the unit's body, do not use water hotter than 40°C, harsh abrasive cleansers, or volatile agents like benzene or
thinner.
y Do not expose the unit body to liquid insecticides or hairsprays.
y When shutting down the unit for one month or more, first allow the Fan mode to operate continuously for about half a day to
allow internal parts to dry thoroughly.
16