Put a low resistor in the input terminal before slide the sliding
function switch to resistor and continuity function may be
cause a buzzer sound
Continuity
Built-in buzzer sound when resistance is less than 50 Ω and sound
off when measured resistance is more than > 300 Ω.
Between 50 Ω to 300 Ω the buzzer maybe sound or off either.
DC A (auto-ranging)
Range
Resolution
0 ~ 40 A
10 mA
40 ~ 200 A
100 mA
200 ~ 300 A
100 mA
Overload protection:
AC A (auto-ranging)
Range
Resolution
0 ~
4 A
10 mA
4 ~ 40 A
10 mA
40 ~ 200 A
100 mA
200 ~ 300 A
100 mA
0 ~
4 A
10 mA
4 ~ 40 A
10 mA
40 ~ 200 A
100 mA
200 ~ 300 A
100 mA
Overload protection:
Accuracy
± 1,0% rdg. + 2 dgt.
± 2,0% rdg. + 2 dgt.
400 A
rms
Accuracy
Frequency
response
± 1,0 % rdg. +
2dgt.
± 1,0 % rdg. +
50 Hz ~ 60 Hz
3dgt.
± 3,0 % rdg. +
3dgt.
± 2,0 % rdg. +
7dgt.
40 Hz ~ 1 kHz
± 2,0 % rdg.
+5dgt.
± 5,0% rdg.+
5dgt.
400 A
rms