– A – Notice messages
A 3
Wheel not suitable for performing the sensitivity
calibration, use a wheel of average dimensions
(typically 5.5"X14") or larger but with a weight
that does not exceed 40 kg.
A 5
Incorrect wheel data for an ALU programme.
Correct the set dimensions.
A 7
The machine is temporarily not enabled to select
the programme requested.
Perform a wheel spin, then repeat the request.
A 20
Ultrasonic sensor calibration template in an
incorrect position during calibration. Bring it to
the position indicated and repeat the calibration.
A 23
Data entry incomplete or incorrect in ALU P. Enter
again correctly.
A 25
Programme not available on this model.
A 26
Programme available only after selecting one
of the following programmes: ALU 1P / ALU 2P /
Motorcycle Dynamic / Motorcycle Alu.
A 31
Optimisation procedure (OPT) already launched
by another user.
A 51
Incorrect wheel clamping (only with the automatic
wheel clamping system).
Repeat the locking operation.
A 52
hub mounting/demounting procedure started
automatic wheel clamping system.
After 30 seconds, the procedure ends automat-
ically.
A Stp
Wheel stop during the spin phase.
A Cr
Spin performed with the guard raised.
Lower the guard to perform the wheel spin.
EM 9580 - Operator's manual
– E – Error Messages
E 1
Sensitivity calibration missing. Perform the sen-
sitivity calibration procedure.
E 2
Error condition on sensitivity calibration.
the sensitivity calibration, paying attention to the
first spin, which must be performed with the wheel
like the subsequent spins.
Take particular care NOT to knock the machine
during calibration.
E 3 I/E 2/3
Error condition at the end of sensitivity calibration.
Repeat the calibration, if the message persists
perform the following checks:
• Correct sensitivity calibration procedure;
• Correct fastening and position of the calibration
weight;
• Mechanical and geometric condition of the cali-
bration weight;
• Geometry of the wheel used.
E 4
a) Error condition on sensor calibration.
Perform the sensor calibration procedure.
b) External sensor missing.
error can be disabled by performing the
following procedure:
-
Select ultrasonic width sensor calibration
and press the Kis knob or the
ENTER button.
E 6
Error condition when executing optimisation
programme.
Repeat the procedure from the beginning.
E 12
External sensor not present or
of this error can be disabled by performing the
following procedure:
-
Select ultrasonic width sensor calibration
and press the Kis knob or the
ENTER button.
E 27
Excessive braking time. If the problem persists,
call in the technical support centre.
E 28
Encoder counting error. If the error occurs fre-
quently, call in the technical support centre.
Repeat