Herunterladen Inhalt Inhalt Diese Seite drucken

Power Supply Connections - Eneo IPB-73M2812M0A Schnellstart Bedienungsanleitung

1/2.8” network camera, 3mp, 2048x1536, day&night, d-wdr, 2.8-12mm, infrared, outdoor
Vorschau ausblenden Andere Handbücher für IPB-73M2812M0A:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3. Inclination limit (Horizontal image alignment): Inclination limited to +/-90° max.
Torque wrench

Power supply connections

Make sure the power is removed before the installation. Camera can work with either
24VAC or 12VDC, dual voltage power and PoE (IEEE Std. 802.3af ). Primary and secondary
grounds are completely isolated to avoid the possible ground loop problems.
1. Plug the network cable into RJ-45 Ethernet Port. If PoE is the unique power, there
will be no need to connect Power terminal.
2. When DC12V or AC24V Local power is necessary, connect the low voltage (DC12V
or AC24V) first, then plug the AC adapter to AC outlets to avoid an improper reset
from power jitter and a damage from the surge voltage when no load.
i
When PoE and local dual power are connected at the same time, local power has
priority.
Downloaded from
www.Manualslib.com
±90°
Lock / Unlock
screw
manuals search engine
EN
9

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis