Herunterladen Inhalt Inhalt Diese Seite drucken

Lubrication; Oiler Setting; Storing - Westfalia 92 86 20 Originalanleitung

Druckluft-nadelentroster
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

removes moisture and dirt from the air, controls the working pressure
and supplies the device perfectly with lubricating oil.
 If necessary, clean the unit with a moist cloth.
 Do not use abrasive or aggressive chemicals as benzene or thinner,
which may dissolve plastic parts.
 Do not allow liquids to enter the unit and never immerse it into liquids.
Water in the compressed air inlet can damage the machine. Therefore it
is recommended to drain the air lines and the compressor regularly! The
air filters should be cleaned at least once a week.

Lubrication

Pneumatic devices have to be lubricated always sufficiently. This is done
continuously and safest by using an oil-fog lubricator. If the oiler is mounted
centrally at the compressor or mounted firmly at the end of the compressed-
air pipe installation, use only a hose with a length of max. 10 m. If the hose
is longer, the nebulisation disappears in the air. The oil floats inside the
hose and does not arrive at the air device.

Oiler Setting

Hose up to 5 m every 2 minutes 1 drop
Hose up to 10 m every minute 1 drop
If you do not have an oiler at yours disposal, please put a few drops of oil
into the compressed-air connection (6) before every machine usage. Lubri-
cate the air needle scaler once more after use, especially if you do not oper-
ate the unit for a long time. Further maintenance work is not necessary.

Storing

 Store the unit indoors in dust and dirt-free location, between 10° C and
30° C. Keep the unit out of reach of children and persons in need of
supervision.
Operation
13