11
Maintenance
12
Technical data
WTB26P-xxxxx1,
WTB26P-xxxxx5
Sensing range max.
30 mm ... 1600 mm
Light spot diame‐
Ø 7 mm / 700 mm
ter/distance
(Typ), Ø 5 mm / 500
mm (Typ),
Supply voltage U
DC 10 ... 30 V
B
Ripple
≤ 5 V
Current consumption
≤ 30 mA
< 50 mA
Output current I
≤ 100 mA
max.
Max. response time
500 μs
Switching frequency
1000 Hz
Enclosure rating
6)
see table
x4, xH, x5, xI: IP66,
IP67, IP69
x9, xB: IP65
Protection class
III
Circuit protection
A, B, C, D
8020354.19RH / 15.01.2021 | SICK
Subject to change without notice
NOTE
Disposal of batteries, electric and electronic devices
•
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
•
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
•
WEEE:
This symbol on the product, its package or in this document,
indicates that a product is subject to these regulations.
SICK sensors are maintenance-free.
We recommend doing the following regularly:
•
Clean the external lens surfaces
•
Check the screw connections and plug-in connections
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
WTB26Pxxxxx4
30 mm ... 3000 mm
1)
Ø 7 mm / 700 mm
(Typ)
DC 10 ... 30 V
≤ 5 V
SS
SS
≤ 30 mA
2)
3)
< 50 mA
≤ 100 mA
4)
2.5 ms
5)
200 Hz
1:
see table
x4, xH, x5, xI: IP66,
IP67, IP69
7)
x9, xB: IP65
III
8)
A, B, C, D
WTB26I-xxxxx1
30 mm ... 2000 mm
1)
Ø 14 mm / 1 m
DC 10 ... 30 V
≤ 5 V
SS
≤ 30 mA
2)
2)
3)
< 50 mA
3)
≤ 100 mA
4)
500 μs
4)
5)
1000 Hz
5)
1:
see table
x4, xH, x5, xI: IP66,
IP67, IP69
7)
x9, xB: IP65
III
8)
A, B, C, D
8)
MAINTENANCE
WTB26I-xxxxx4
30 mm ... 3000 mm
1)
Ø 14 mm / 1 m
DC 10 ... 30 V
≤ 5 V
SS
≤ 30 mA
2)
< 50 mA
3)
≤ 100 mA
2.5 ms
4)
200 Hz
5)
1:
see table
1:
x4, xH, x5, xI: IP66,
IP67, IP69
7)
7)
x9, xB: IP65
III
A, B, C, D
8)
11
1)
15