xChargeIn
WARNING!
Risk of electric shock and fire hazard!
● For terminals X1-X4 (Ethernet connections as well as terminals for en-
● The fuse on the fuse holder F1 must not be used to switch off the charg-
● The connection panel is never permitted to be left open unattended. Be-
7.2

Required tools

The following tools are required for the electrical installation:
7.3

Power supply

The power supply (supply line) must be hardwired to an existing domestic in-
stallation and comply with the applicable national regulations.
Mains disconnector
The charging station does not have its own power switch. The line circuit
breaker of the supply line serves as a mains disconnector.
Selection of RCD / fault-current circuit breaker
Each charging station must be connected via a separate RCD (Residual
Current Device / fault-current circuit breaker). No other consumers may be
connected to this circuit.
An RCD with at least Type A must be used since all xChargeIn variants have
an internal DC fault current monitoring ≥ 6 mA.
Installation manual V1.05
© EATON
abling input and switching contact output), only voltages and circuits are
permitted to be connected which have a safe separation to dangerous
voltages (for example sufficient insulation).
Supply the terminal for the switching contact output (X2) exclusively from
voltage sources which have a protective extra-low voltage.
ing station. To interrupt the power supply, always use the circuit line
breaker.
fore leaving the charging station, the connection panel cover must be
mounted.
Flathead screwdriver for supply terminals (blade width 5.5 mm)
Flathead screwdriver for terminals X1/X2 (blade width 3.0 mm)
Phillips head screwdriver PH2
Mounting tools for cable screw connections M16 (width across flats 20
mm) and M32 (width across flats 36 mm)
®
LSA+
insertion tool (optional)
Connections and wiring