44/54
Maintenance and repair
Bosch Rexroth AG, MIT: LU 2, 3 842 358 814/2018-12
• Resistance to media and contamination does not mean that functional safety is
guaranteed in every case.
– Liquids that thicken as they evaporate and become highly viscous or adhesive
(sticky) can lead to malfunctions.
– If they get carried onto systems with rollers, media which have a lubricating effect
can lead to a reduction in the drive power that can be transmitted via friction.
In such instances, special care must be taken when planning the system, and the
maintenance intervals must be correspondingly shortened.
11 Maintenance and repair
High electrical voltage!
Risk of serious injury or death from electric shock.
Disconnect the system component requiring maintenance or servicing
before starting.
Secure the system against being unintentionally switched on again.
High pneumatic pressure!
Risk of serious injury or death.
Switch off the compressed air supply to the relevant system component before
performing any maintenance or repair work.
All pneumatic cylinders must be depressurized (vented).
Secure the system against being unintentionally switched on again.
Hot electric motor surfaces during operation!
Risk of burns from touching hot surfaces above 65 °C.
Install appropriate guards.
Allow the system to cool down for at least 30 minutes before performing
maintenance and/or servicing.
• Only inspect and adjust continuous conveyors that are in motion or operation when
the safety guards are in place.
• Adhere to DIN EN ISO 13857 when removing or replacing guards and/or bypassing
safety equipment.
• Test runs with open paneling should only be performed by a person with
appropriate knowledge and experience using tip switches, and if there is no
possibility of interference from other switching devices.
WARNING